Water chiller
A water chiller is a refrigeration machine that removes heat from water and rejects it to ambient air or to a cooling tower, producing chilled water for cooling duty. The standard rating condition is 7 °C supply and 12 °C return. Vapor-compression chillers are built around four components — compressor, evaporator, condenser and expansion device — and are selected mainly by cooling capacity, compressor type, condensing method and part-load efficiency.
Product series
Air-cooled chillers
No cooling tower or condenser water loop, so installation is simpler and the unit can be placed on a roof or in a yard. Capacity is limited by ambient air temperature, and the condenser coil needs periodic cleaning.
Water-cooled chillers
Condenser heat rejected to a cooling tower. Higher efficiency and more stable performance in hot climates, at the cost of a tower, pumps and water treatment.
Screw-type chillers
Twin-screw compressors with continuous capacity modulation, typical COP of 4.5–6.0. Common choice for medium and large process and HVAC loads.
Centrifugal and magnetic-bearing chillers
Centrifugal compression with oil-free magnetic bearings, typical COP above 6.0 at design condition and strong part-load performance. Suited to large plants with long operating hours.
Low-temperature and explosion-proof chillers
For chilled water or brine below 0 °C, and for hazardous areas requiring explosion-proof motors and electrical enclosures.
Typical technical parameters
| Parameter | Typical range | Note |
|---|---|---|
| Chilled water supply / return | 7 °C / 12 °C | Standard rating condition |
| Cooling capacity | approx. 30–2,000 kW | Model and series dependent |
| Compressor type | Scroll / screw / centrifugal | Selected by capacity and part-load profile |
| Condensing method | Air-cooled / water-cooled | Site and climate dependent |
| Nominal COP | Screw 4.5–6.0; centrifugal above 6.0 | At design condition |
| Refrigerant | HFC or low-GWP alternative | Per project and local regulation |
Ranges are indicative. Final selection follows the cooling load calculation, ambient or tower water conditions, part-load profile and electrical supply available on site.
Selection notes
Three inputs drive the selection: cooling load and its profile, condensing conditions (design ambient or tower approach), and part-load behavior. A chiller chosen on full-load efficiency alone can perform poorly in a plant that runs at 40% load most of the year — which is why IPLV or part-load data matters as much as the nominal COP.
Also confirm: chilled water flow and pressure drop, allowable footprint and weight, noise limit at the nearest sensitive receiver, refrigerant charge limits, and the electrical capacity available.
Frequently asked questions
What is the difference between COP and IPLV?
COP describes efficiency at a single full-load design point. IPLV integrates efficiency across part-load ratios, so it better reflects a plant that rarely runs at 100%. Compare both when selecting.
Air-cooled or water-cooled — which should I choose?
Water-cooled is more efficient where a cooling tower can be installed and water treatment is managed. Air-cooled avoids the tower, the condenser water pumps and the water treatment, and suits sites where those are impractical.
What chilled water temperatures can be achieved?
Standard is 7 °C supply / 12 °C return. Lower supply temperatures to 0 °C and below require a low-temperature machine and a glycol or brine secondary loop.
How much maintenance does a chiller need?
Routine items are condenser cleaning, refrigerant charge and leak check, oil and filter service on oil-lubricated machines, control calibration and safety-device testing. Magnetic-bearing machines have no oil circuit to service.
Why does a chiller trip on high pressure in summer?
Usually condenser heat rejection is inadequate — fouled coil, blocked tower, low condenser water flow, or non-condensable gas in the circuit. Check the condensing side before adjusting the charge.
Can several chillers be combined?
Yes. Multiple units are staged by a plant controller for redundancy and part-load efficiency; the controller sequence and changeover logic should be defined at design stage.
Related reading
- What is a water chiller? Full guide
- How to size a water chiller
- COP vs IPLV explained
- How a water chiller works
Request a quotation
Send the cooling load calculation, chilled water supply and return temperatures, design ambient or tower conditions, part-load profile and available power supply. We return a selection sheet with model, capacity, COP/IPLV basis and the assumptions used.