Start with the material flow, not the machine
Sludge arrives wet, leaves dry, and the distance between those two points defines the layout.
| Zone | Function | Space guide |
|---|---|---|
| Reception and storage | Dewatered cake buffer, 3–7 days | 1.5–2.0 m² per tonne of daily cake |
| Feed | Hopper, conveyor or pump | 2 m working aisle |
| Drying | Heat pump unit and drying chamber | Per model, plus 1 m service |
| Discharge | Dry product conveyor and skip | Skip length plus 3 m turning |
| Condensate | Collection tank and transfer | 1–2 m², bunded |
| Odor control | Biofilter or carbon unit | 2–4 m² |
| Control | Panel with a view of the feed | 2 m clear front |
If the skip cannot be exchanged without reversing 40 m, the plant will be operated badly. Access is a process requirement.
Foundation and floor loading
| Capacity (wet t/d) | Typical installed weight | Footprint | Load to allow |
|---|---|---|---|
| 1–3 | 3–6 t | 6 × 3 m | 10 kN/m² |
| 5–10 | 8–15 t | 10 × 4 m | 15 kN/m² |
| 20–30 | 20–35 t | 15 × 6 m | 20 kN/m² |
| 50+ | 40–70 t | Modular, 20 × 10 m | 25 kN/m² |
The foundation must be level to within 3 mm over the unit length, and it must be rigid: a drying chamber that distorts will leak air, and an air leak is a capacity loss. On a suspended slab, check the load with the chamber full of wet sludge, not empty.
Provide a 100–150 mm curb around the drying area and a floor fall to a collection sump. Sludge spills, washdown water and condensate all end up on the floor, and none of them should reach a surface water drain.
Drainage and condensate
Condensate from sludge drying is not clean water. It carries dissolved organics, ammonia and fine solids.
| Parameter | Typical range | Implication |
|---|---|---|
| COD | 1,000–8,000 mg/L | Requires treatment before discharge |
| Ammonia nitrogen | 200–1,500 mg/L | Biological or stripping treatment |
| Suspended solids | 200–2,000 mg/L | Filtration or return to the works |
| pH | 6.5–8.5 | Neutral to slightly alkaline |
| Sulfide | Present in some sludges | Odor and corrosion |
Route condensate to the works inlet or to a dedicated treatment step, never to storm drainage. Use corrosion-resistant pipe — stainless or PE — with a fall of at least 1:100 and rodding points at every change of direction. A condensate line that blocks will flood the drying chamber.
Ambient conditions and the building envelope
| Condition | Effect | Measure |
|---|---|---|
| Below 5 °C | Heat loss, defrost, reduced capacity | Insulate the chamber, heat the space |
| Above 40 °C | Compressor head pressure, reduced life | Ventilate the plant area |
| High humidity | Condensation on cold surfaces | Insulate, ventilate |
| Dusty atmosphere | Coil and filter fouling | Pre-filter, clean schedule |
| Corrosive atmosphere (H2S) | Coil and panel corrosion | Coated coil, IP-rated panel |
The dryer performs most consistently in a stable, insulated space. An open-sided shed in a northern winter will lose 20%–30% of its capacity to the environment and will defrost constantly.
Odor: design it in, not on
| Measure | Purpose | Note |
|---|---|---|
| Enclosed drying chamber | Contains the air stream | Doors with seals |
| Slight negative pressure | Stops fugitive release | Extract fan with VFD |
| Odor treatment | Biofilter, carbon, or chemical scrubber | Size on air flow, not on machine count |
| Duct velocity | Above 8 m/s | Prevents settlement |
| Stack height | Per dispersion study | Above roof line and nearby intakes |
A dryer that is mechanically perfect but odorous will be shut down by the neighbors. Treat odor as a design parameter with an airflow figure, not as an accessory.
Services
| Service | Requirement |
|---|---|
| Power | 380–415 V, 3-phase, sized on total connected load plus 20% |
| Water | Washdown point within 10 m |
| Compressed air (if used) | 6–8 bar, dry, filtered |
| Drain | Condensate and washdown, separate |
| Lighting | IP65, sufficient to read instruments |
| Fire | Detectors suitable for the dust level, extinguishers at the exit |
| Weighing | Platform scale for incoming cake and outgoing product |
Weighing is often omitted and always regretted. Without incoming and outgoing weights, the only measure of performance is the moisture reading, and the mass balance cannot be closed.
Longkang Environmental Equipment Co., Ltd. supplies a general arrangement drawing with the foundation loads, connection positions and service requirements marked, so the civil works can be completed before the unit is shipped. Phone: +86 400-878-0280 | +86 130-0200-1280
Questions from project engineers
How much floor area does a 10 t/d dryer need?
Plan on about 10 m × 4 m for the unit plus 2 m of working aisle, and a further 20–30 m² for storage, discharge and odor control. Total building area is typically 80–120 m².
Can the dryer be installed outdoors under a canopy?
Yes, if the unit is specified for outdoor use and the ambient range is respected. The control panel and the heat pump need protection from rain and direct sun; the drying chamber needs insulation regardless.
Does the floor need to be acid-resistant?
Not usually, but it needs to be sealed and resistant to washdown. Where the sludge is industrial and acidic, use an epoxy coating and a bunded area.
How is the dry product removed?
By screw conveyor or belt to a skip, or into big bags. The product is dusty, so enclose the transfer points and fit a local extract. Do not rely on a manual shovel: it will not be done.
What headroom is required?
Typically 4.5–6 m for a belt dryer with a feed hopper and discharge conveyor, and 3.5–4 m for a compact cabinet unit. Check the hopper loading height against the loader or conveyor that feeds it.
Is planning permission usually required?
In most jurisdictions yes, because of the building, the odor potential and the traffic. Start the application with the odor and noise assessment, not after the equipment is ordered.