Explosion-Proof Chillers for Chemical and Hazardous Areas

Classification comes before selection

A chiller for a hazardous area is specified by the area, not by the machine. Three pieces of information are needed:

  1. Zone: where the flammable atmosphere can occur, and for how long.
  2. Gas group: how easily the gas ignites, IIA (propane), IIB (ethylene), IIC (hydrogen, acetylene).
  3. Temperature class: the maximum surface temperature the gas can tolerate, T1 (450 °C) to T6 (85 °C).
Zone Definition Typical chiller approach
Zone 0 Continuous flammable atmosphere No chiller inside; remote plant only
Zone 1 Likely during normal operation Ex-rated machine or remote plant
Zone 2 Unlikely, short duration Ex-rated or purged machine
Safe area No flammable atmosphere Standard machine, ducted air if needed

Most chemical plants put the chiller in a safe area and circulate chilled water or glycol into the hazardous zone. That is cheaper, easier to maintain and easier to certify than an Ex machine inside Zone 1.

Protection concepts and what they mean

Concept Code How it works Suited to
Flameproof enclosure Ex d Contains an internal explosion Compressors, motors in Zone 1
Increased safety Ex e Prevents sparks and hot spots Terminal boxes, luminaires
Pressurised Ex p Keeps flammable gas out with air Control panels, large enclosures
Intrinsic safety Ex ia/ib Limits energy in the circuit Sensors, instrumentation
Encapsulation Ex m Seals the components Small devices
Dust protection Ex t Enclosure for combustible dust Flour, sugar, coal plants

A chiller in a hazardous area typically combines several: Ex d motors, Ex e terminals, Ex p panel, Ex ia sensors. The combination is stated on the nameplate and in the certificate.

Temperature class and surface temperature

Class Maximum surface temperature Gases that require it
T1 450 °C Most common gases
T2 300 °C Ethylene, some solvents
T3 200 °C Hydrogen sulfide, petrol
T4 135 °C Diethyl ether, acetaldehyde
T5 100 °C Rare, special cases
T6 85 °C Carbon disulphide

A compressor discharge line at 90 °C is acceptable in a T4 area but not in a T5 area. That constraint can eliminate a high-condensing-temperature design, which is why the condenser and the refrigerant choice matter as much as the motor.

Refrigerant choice in hazardous areas

Refrigerant Flammability Comment
R134a Non-flammable Common, A1
R513A Non-flammable A1, lower GWP
R410A Non-flammable A1, higher pressure
R32 A2L, mildly flammable Adds a second ignition source risk
Ammonia B2L, toxic and flammable Needs a dedicated machine room
CO₂ Non-flammable, high pressure Transcritical, specialist

Adding a flammable refrigerant to a hazardous area complicates the risk assessment. For most chemical plants, an A1 refrigerant is the simpler approval path.

Arrangement options

Arrangement Capital Maintenance Certification
Standard chiller in a safe area, glycol to the process Lowest Easy Simple
Standard chiller with ducted outdoor air and remote condenser Low Easy Moderate
Ex-rated packaged chiller in Zone 2 High Specialist Complex
Ex-rated split system, condenser in a safe area Medium Moderate Moderate
Ammonia plant in a dedicated room High Specialist Complex

The first option should always be considered first. Piping glycol 30 m is usually cheaper than certifying a machine for Zone 1.

Installation requirements

Item Requirement
Earthing and bonding All metal parts bonded, resistance below 1 Ω
Cable glands Ex-rated, matched to the cable
Cable type Armored or conduit, no exposed flexibles
Isolation Lockable, outside the hazardous area
Ventilation Designed for the area, with gas detection
Gas detection interlock Trips the plant on alarm
Hot surfaces Insulated and guarded to the T class
Maintenance procedure Gas clearance before opening

The interlock matters: if gas is detected, the chiller should stop, not continue running with a sparking contactor. The trip should be hard-wired, not dependent on the BMS.

Reactor cooling: the process side

Requirement Detail
Temperature stability ±0.5 K is often required for reaction control
Turn-down 10%–100% with stable temperature
Fluid Glycol or a heat transfer fluid, not water
Control Cascade from reactor temperature to chiller capacity
Buffer A tank to smooth exothermic peaks
Safety Relief and over-temperature protection on the reactor side

A reactor cooling load can change by 50% in a minute when a reaction starts. The chiller needs a buffer tank and a fast-acting control valve, or the reactor temperature will run away.

A configuration example

A fine chemical plant, 350 kW reactor cooling at −5 °C, Zone 2 area:

Item Selection Reason
Chiller 2 × 200 kW screw, glycol 35% N+1, −8 °C leaving
Location Safe area, 25 m from the reactor building Avoids Ex certification
Panel Ex p purged, mounted in the safe area Certified control
Piping Welded stainless, no flanged joints in the zone Leak reduction
Buffer 3 m³ Exothermic peak smoothing
Detection Gas detection interlocked to the chiller Safety
Earthing Bonded grid, below 1 Ω Static control

The distance from the reactor building is the key decision: it removes the need for an Ex-rated compressor and makes maintenance possible without a gas clearance certificate.

Longkang Environmental Equipment Co., Ltd. supplies hazardous-area schemes with the zone drawing, the Ex certificate list and the interlock schedule, so the installation can be inspected against a single document set. Phone: +86 400-878-0280 | +86 130-0200-1280

Questions from chemical plant engineers

Can a standard chiller be installed in Zone 2?

Only with additional protection, such as pressurisation or a local Ex enclosure, and with a documented risk assessment. In most jurisdictions a standard machine is not acceptable in Zone 2 without modification.

What is the cheapest compliant arrangement?

A standard chiller in a safe area with glycol piped to the process. It avoids Ex equipment entirely and is easier to maintain.

How is the temperature class determined?

By the gas present and its ignition temperature, taken from the plant’s hazardous area classification drawing. Do not guess: the drawing is the reference.

Does the refrigerant need to be non-flammable?

It is strongly preferred. A2L refrigerants add a second flammable source and complicate the assessment; A1 refrigerants keep the analysis simple.

How often must Ex equipment be inspected?

Typically annually for visual and close inspection, with a detailed inspection every three years. The regime is defined in the local electrical code for hazardous areas.

What happens if gas is detected?

The chiller should trip automatically through a hard-wired interlock, the area should be ventilated, and the plant should not restart until the atmosphere is clear and the cause is found.