Classify the fault before opening the panel
| Pattern | Category | First place to look |
|---|---|---|
| Alarm at start, nothing runs | Interlock or supply | E-stop, door switch, phase |
| Runs, but no drying | Airflow or refrigerant | Filter, fan, coil, charge |
| Product too wet, temperature normal | Residence time or feed rate | Feed rate, belt speed |
| Product too dry, energy high | Control or humidity sensor | Humidity sensor, setpoint |
| Alarm after hours of running | Heat build-up or blockage | Coil, filter, condensate |
| Random alarms | Wiring or sensor drift | Screens, sensor comparison |
High temperature
| Cause | Confirm by | Action |
|---|---|---|
| Low airflow | Filter differential high, fan current low | Clean filter, check belt |
| Fan failure | Fan not turning, alarm on VFD | Repair or replace |
| Overcharge or hot gas valve stuck | Discharge pressure high | Check charge, valve |
| Feed stopped, chamber empty | Feed motor fault, hopper bridging | Restore feed |
| Sensor error | Independent thermometer disagrees | Replace sensor |
High temperature with an empty chamber is common after a feed blockage: the dryer keeps heating air with nothing to evaporate. The feed alarm should stop the compressor, and if it does not, that interlock is the real fault.
Low temperature / no heating
| Cause | Confirm by | Action |
|---|---|---|
| Compressor not running | Contactor, overload, code | Electrical check |
| Low refrigerant charge | Subcooling low, suction low | Leak test and recharge |
| Defrost stuck | Coil iced, defrost sensor | Check sensor and valve |
| Air leak into the chamber | Cold spot at a seal, humidity low | Seal test |
| Ambient too low | Room below 5 °C | Heat the space |
A dryer that cannot reach temperature in winter is often not faulty: it is losing heat through an uninsulated chamber or an open door. Check the envelope before the refrigerant.
Airflow and fan faults
| Alarm | Cause | Check |
|---|---|---|
| Fan overload | Belt too tight, bearing seized, blockage | Belt tension, bearing, duct |
| Low differential pressure | Belt broken, fan eroded, damper closed | Belt, impeller, damper |
| High differential pressure | Filter blocked, duct crushed | Filter, duct route |
| VFD fault | Overcurrent, overheat, earth fault | Motor insulation, heatsink |
Fans in sludge service erode. If the impeller is worn, the airflow falls gradually and nobody notices until the capacity is 20% down. Inspect the impeller annually.
Compressor and refrigeration faults
| Code type | Meaning | Check |
|---|---|---|
| High pressure | Condensing pressure above limit | Coil, fan, charge, ambient |
| Low pressure | Suction below limit | Charge, restriction, low load |
| Overload | Current above limit | Voltage, winding, mechanical |
| High discharge temperature | Above 95 °C | Charge, airflow, sensor |
| Oil pressure | Below limit | Oil level, heater, pump |
| Defrost fault | Cycle not completing | Sensor, valve, timer |
The coil in a sludge dryer fouls faster than in any other application. A high-pressure alarm on a dryer is a coil-cleaning alarm until proven otherwise.
Condensate faults
| Symptom | Cause | Action |
|---|---|---|
| High level alarm | Pump failed, strainer blocked, drain blocked | Clean, test pump |
| Water in the chamber | Tray overflow, trap failed | Clear, replace trap |
| Odor in the plant room | Trap dry or bypassed | Refill, repair trap |
| Condensate cloudy with solids | Carry-over from the chamber | Check airflow and feed |
Condensate is the second-largest output of the process after dried product. If it is not removed reliably, the plant stops.
Feed and discharge faults
| Alarm | Cause | Action |
|---|---|---|
| Feed overload | Oversized object, wet cake, blockage | Metal detection, reduce rate |
| Hopper bridging | Angle, moisture, polymer dose | Agitator, angle, dose review |
| Discharge blockage | Product too wet, chute too narrow | Moisture check, widen |
| Belt misalignment | Uneven feed, roller | Center feed, adjust |
| Emergency stop | Operator action or faulty circuit | Investigate before reset |
Sensors and communication
| Symptom | Cause | Check |
|---|---|---|
| Humidity reads 100% constantly | Condensate on the sensor | Relocate, dry, recalibrate |
| Temperature offset by a fixed amount | Sensor drift | Compare, replace |
| Controller offline | Supply, cable, address | 24 V, continuity, DIP |
| BMS value frozen | Communication timeout | Cable, termination |
A humidity sensor coated with condensate is the most common cause of a dryer producing over-dry product: the controller believes the air is saturated and keeps drying. Clean the sensor at every service.
A sequence that works
- Read the alarm with the timestamp and the operating state.
- Check the material path: hopper, feeder, chamber, discharge.
- Check the air path: filter, fan, duct, seals.
- Check the condensate path: tray, trap, pump.
- Check the refrigerant only after the first four.
- Record the readings before and after the repair.
| Measurement | Normal | Points to |
|---|---|---|
| Chamber temperature | 40–75 °C per setting | Control or airflow |
| Exhaust humidity | Falling as product dries | Sensor or airflow |
| Filter differential | Below the marked limit | Filter |
| Compressor current | Below FLA | Charge or mechanical |
| Condensate flow | Roughly equal to evaporation | Blockage or carry-over |
Longkang Environmental Equipment Co., Ltd. supplies a fault table matched to the controller fitted to each unit, because the same code number is not used consistently across generations. Phone: +86 400-878-0280 | +86 130-0200-1280
Questions from maintenance engineers
Why does the dryer trip on high pressure after a filter change?
A new filter fitted with the wrong orientation, or a plastic wrapper left inside, restricts airflow. Check the differential pressure and the airflow direction arrow.
The product is too dry and the energy has gone up. Why?
Usually the humidity sensor. If it reads high, the controller keeps drying. Clean or replace the sensor and re-check the setpoint.
Can I run the dryer with the condensate pump failed?
For a few hours, if the tray is monitored and emptied manually. Overnight, no: the chamber will flood and the insulation will be ruined.
What causes ice on the heat pump coil?
Low refrigerant charge, a defrost sensor fault, or operation below the rated ambient. Ice on the coil lowers capacity and eventually stops the machine.
How do I clear a blocked discharge chute?
Stop the feed, let the chamber cool, isolate the conveyor, and clear from the access hatch with the correct tool. Never reach into a running conveyor, and never use a hose on an energised panel.
How many alarms before I call a service engineer?
One alarm with a clear cause, such as a blocked filter, can be handled in-house. Three alarms of the same type in a week, or any oil pressure or compressor alarm, warrants a service visit.