First, establish what the machine is actually doing
Weigh the feed and the product over a measured period, and measure both moistures by oven drying:
- Feed rate (t/h) = wet feed weight ÷ hours.
- Dry solids = feed rate × (1 − feed moisture).
- Product rate = dry solids ÷ (1 − product moisture).
- Actual evaporation = feed rate − product rate, in t/h.
- Specific energy = measured kWh ÷ actual evaporation, in kWh/t water.
Compare the actual evaporation with the guarantee. A machine rated 0.71 t/h evaporating 0.45 t/h is at 63% of capacity, and the specific energy will be correspondingly worse.
The six causes, in diagnostic order
| # | Cause | Signature | Check |
|---|---|---|---|
| 1 | Feed wetter than design | Feed at 84% instead of 80%; product still at target | Measure feed moisture for a full shift, not one grab sample |
| 2 | Sludge character changed | Stickier, more fibrous, or changed source | Compare with the sample used for the design |
| 3 | Heat exchanger fouling | Specific energy up, approach temperatures worse | Coil and fin inspection, approach calculation |
| 4 | Air leakage into the loop | Capacity down, condensate volume down, humidity low | Seal inspection, pressure test of the chamber |
| 5 | Refrigeration fault | Low suction or high discharge, compressor cycling | Pressures, superheat, compressor current |
| 6 | Mechanical or control issue | Conveyor speed, residence time, premature discharge | Belt speed, discharge moisture, control setpoints |
Cause 1 is by far the most common, and it is the one the dryer supplier cannot fix. A feed at 84% instead of 80% contains 25% more water per tonne of dry solids; the machine is not underperforming, it is being asked to do more work.
The mass balance that settles the argument
Design basis: 10 t/day at 80% → 30%, 7.14 t/day evaporation.
Actual: feed 10 t/day at 84%, product at 30%.
| Design | Actual at 84% feed | |
|---|---|---|
| Dry solids | 2.0 t/day | 1.6 t/day |
| Water to evaporate | 7.14 t/day | 8.4 t/day |
| Product | 2.86 t/day | 2.29 t/day |
| Evaporation required per tonne of feed | 0.71 t | 0.84 t |
The dryer is producing a drier product but less of it. If it can only evaporate 7.14 t/day, the throughput falls to 8.5 t/day of feed — a 15% shortfall that has nothing to do with the equipment.
Checking the dryer itself
| Check | Normal | Action if abnormal |
|---|---|---|
| Evaporator approach (air in − evaporating temp) | 5–8 K | Clean the coil, check airflow |
| Condenser approach (condensing temp − air out) | 3–6 K | Clean, check refrigerant charge |
| Compressor current | Within nameplate | Investigate refrigeration fault |
| Airflow at the fan | Within 10% of design | Check belt, fan direction, filters |
| Chamber leakage | No measurable infiltration | Reseal doors, flanges, conveyor entry |
| Condensate flow | Proportional to evaporation | Low flow confirms leakage or bypass |
| Discharge moisture | Within target band | Adjust residence time |
Air leakage is worth particular attention: a closed-loop dryer depends on recirculating a known mass of air. A leaking door gasket lets humid air out and dry air in, which lowers the humidity in the loop, reduces the dew point that the evaporator can work against, and cuts capacity — while every temperature reading still looks plausible.
What to do about a wetter feed
- Fix the dewatering first. A 2 percentage point improvement at the belt press removes more water than 10% extra dryer capacity, at a fraction of the cost.
- Add polymer optimization. Dosage, mixing energy and residence time in the thickener all affect the final cake moisture more than most operators expect.
- Buffer the feed. A silo that averages the moisture over a shift protects the dryer from spikes that would otherwise force it to run at reduced throughput for hours.
- Re-rate the dryer honestly. If the feed is permanently at 84%, the machine needs 18% more evaporative capacity; retrofitting an extra heat pump module or extending the chamber is usually cheaper than a new dryer.
Acceptance testing that avoids the dispute
At commissioning, run a witnessed test of at least 8 hours:
- Record feed weight, feed moisture (three samples), product weight, product moisture (three samples).
- Record electricity consumption over the same period.
- Calculate evaporation rate and specific energy.
- Compare with the contracted values, corrected for ambient temperature if the guarantee states a correction curve.
- Sign the sheet with both parties present.
A capacity guarantee without a stated feed moisture, target moisture and ambient condition is not a guarantee — it is an aspiration.
Frequently asked questions
Why does my dryer only reach 60% of rated capacity?
Check feed moisture first. A feed at 84% instead of 80% explains about 15% of a shortfall; combined with a fouled exchanger and a leaking chamber it explains 40%. Measure before concluding the machine is undersized.
Does cold weather reduce capacity?
Yes. A heat-pump dryer loses 5%–15% of capacity at low ambient because the evaporator has less heat to draw from. If the guarantee was for 20 °C and the plant runs at 5 °C, some of the shortfall is expected — check whether the contract includes an ambient correction.
Can I just speed up the conveyor?
No. Speeding up reduces residence time and raises the product moisture; the evaporation rate is set by the heat input, not by the belt speed. Belt speed should be adjusted to hold the target moisture, not to chase tonnage.
Is the compressor the likely culprit?
Less likely than the feed. A compressor fault shows as abnormal pressures and a rising specific energy; if pressures are normal and the product is at target but there is simply less of it, the dryer is doing its job with a wetter feed.
What if the sludge itself has changed?
Then the design basis is void. Test the new sludge, get a revised capacity and energy figure, and decide whether to adjust the dewatering, the dryer, or the target moisture. Do not accept a verbal assurance that “it will be fine”.
How do I prove the capacity at acceptance?
An 8-hour witnessed test with weighed feed and product, oven moisture tests, and a signed record of electricity consumption. Anything shorter is a demonstration, not a test.
Longkang Environmental Equipment Co., Ltd. states the capacity guarantee against a measured feed moisture, target moisture and ambient temperature, and provides the test procedure so acceptance is a measurement rather than an argument. Phone: +86 400-878-0280 | +86 130-0200-1280