| From → to (wet basis) | Water evaporated per tonne of feed | Relative energy | Comment |
|---|---|---|---|
| 80% → 60% | 500 kg | 0.7 | Mechanical dewatering territory; drying is wasteful here |
| 80% → 40% | 667 kg | 0.93 | Partial drying, easy handling |
| 80% → 30% | 714 kg | 1.00 | Reference case |
| 80% → 20% | 750 kg | 1.05 | +5% energy for 10 points |
| 80% → 10% | 778 kg | 1.15–1.25 | +15%–25% energy for the last 10 points |
The last row is why the target should be justified by the downstream route: the energy penalty for the final increment is real, and it buys nothing if the cement kiln only needs 30%.
The mass balance, step by step
For 10 t/day of dewatered sludge at 80% moisture, targeting 30%:
- Dry solids = 10 × (1 − 0.80) = 2.0 t/day. This does not change during drying.
- Product mass at 30% moisture = 2.0 ÷ (1 − 0.30) = 2.86 t/day.
- Water evaporated = 10 − 2.86 = 7.14 t/day.
- Volume reduction = 71% — the shipment leaving the site is less than a third of what arrived.
At 20% target: product = 2.0 ÷ 0.8 = 2.5 t/day, evaporation 7.5 t/day, volume reduction 75%. The extra 5 percentage points cost 0.36 t/day of evaporation for 0.36 t/day less product — worth it only if the downstream route pays for it.
What limits the achievable moisture
| Limit | Effect | Practical consequence |
|---|---|---|
| Air dew point in a closed-loop dryer | Below about 10%–15% moisture the driving force collapses | 10% is near the practical floor for heat-pump drying |
| Material stickiness at 55%–65% | Fouling, blockage, reduced throughput | Design the dryer to pass through quickly |
| Dust above 15% dryness | Handling and fire risk | Closed conveying, spark detection |
| Heat exchanger surface area | Determines the achievable final moisture at a given residence time | Oversizing the dryer is the usual answer |
A heat-pump dryer can reach 10% in a laboratory; in a plant, 15%–20% is a realistic floor for a continuous machine handling municipal sludge, and 25%–30% is where most projects settle on cost grounds.
Frequently asked questions
Can a heat-pump dryer reach 10% moisture?
It can, with enough surface area and residence time, but the specific energy rises by 15%–25% and the material becomes dusty. Unless the downstream route requires it, 20%–30% is the better operating point.
Why does my dryer stop at 35% when the specification says 20%?
Usually residence time: the material leaves before it is dry. Check the feed rate against the design, the internal conveying speed, and whether the heat exchanger is fouled. The second most common cause is a wet feed that is wetter than the design value — a dewatering failure upstream looks exactly like a dryer failure.
Does the incoming moisture matter?
Enormously. A feed at 82% instead of 80% adds 11% to the water to be evaporated and 11% to the energy, and it usually arrives as a surprise. The dewatering performance should be measured, not assumed.
What happens if the sludge is over-dried?
It becomes a dust hazard, it re-wets poorly, and the energy bill rises. It also makes the dried product harder to pelletise or blend. The control system should target a band, not a minimum.
Is 60% moisture enough to avoid drying?
Only if the downstream route accepts it. For landfill in China, 60% is a common acceptance limit, so mechanical dewatering alone may be enough. For incineration or cement kilns, 60% usually carries too much water and too little calorific value.
How is the final moisture measured?
By oven drying a sample at 105 °C to constant weight, not by a handheld meter. Handheld meters are useful for trending but not for acceptance testing, and the sampling point matters — take it from the discharge, not from the surface of the pile.