Heat pumps · Chillers · Sludge drying systems
Heating · Hot water

Air-source heat pump water heaters

Air-source heat pump water heaters producing 55–60°C domestic and process hot water for hotels, schools, hospitals, factories and pools.

Air-source heat pump water heaters
55–60°C Hot water supply
3.0–4.5 Typical COP
Hotels / schools / hospitals / factories Applications
Air-source / low-ambient / high-temperature Options

Air-source heat pump water heater

An air-source heat pump water heater is a device that uses a vapor-compression cycle to move low-grade heat from ambient air into domestic hot water, rather than generating heat by burning fuel or passing current through a resistance element. It has four core components — compressor, evaporator, condenser and expansion device. For each unit of electricity consumed, it typically delivers three to four units of heat at nominal conditions, giving a heating COP of 3.0–4.5.

Product series

Commercial circulating units

For hotels, schools, hospitals and factory dormitories. Multiple units operate in parallel and charge a large insulated storage tank; variable-frequency water supply keeps delivery temperature stable at peak draw-off.

Residential split and monobloc units

For homes and small premises. 220 V single-phase supply, matched with a 150–500 L tank, installed on a balcony, roof or external wall.

Ultra-low-temperature units

For severe cold regions. Enhanced vapor injection (EVI) raises low-temperature capacity and reduces the drop-off in heating output as ambient temperature falls.

High-temperature units

Delivering water above 60 °C for process hot water and light industrial heating duty.

Pool heating units

Corrosion-resistant wetted parts for chlorinated pool water, holding pool temperature at setpoint year-round.

Typical technical parameters (commercial units, excerpt)

Parameter Typical range Note
Rated outlet water temperature 55 °C Standard domestic hot water setpoint
Nominal heating COP 3.0–4.5 Falls as ambient temperature drops
Heating capacity per unit approx. 4.5–88 kW Model dependent
Ambient operating range −5 to 40 °C (lower for LT models) Select by climate
Power supply 220 V / 380 V Three-phase for larger commercial units
Core components Scroll compressor, plate or coaxial heat exchanger Per actual configuration

These are industry-typical reference ranges, not contractual values for a specific model. Longkang issues a model-specific parameter sheet based on the actual project conditions and engineering review.

Applications and sizing notes

Central hot water: 24-hour guest room supply in hotels, morning and evening peak demand in school dormitories, continuous supply in hospitals, bulk supply in factory dormitories, plus pool heating and space heating.

Sizing rests on three calculations: daily hot water volume, peak-hour factor, and storage tank volume — then a low-temperature capacity check against the local winter design temperature. A system sized only on summer capacity will underperform in the coldest two weeks of the year.

Frequently asked questions

How much electricity does an air-source heat pump water heater use per day?

It depends on daily volume, inlet water temperature and COP. Heating 1 tonne of water from 15 °C to 55 °C at a COP of 4 consumes roughly 11–12 kWh.

Does it work in winter?

Yes, but COP falls as ambient temperature drops. In severe cold regions, specify an ultra-low-temperature model and verify low-temperature heating capacity rather than nominal capacity.

How large should the storage tank be?

Commonly 30%–60% of daily hot water volume; take the upper end where draw-off is concentrated in a short peak.

Is it cheaper to run than an electric resistance heater?

In most operating conditions yes. A heat pump delivers 3.0–4.5 units of heat per unit of electricity; resistance heating delivers close to 1.

How often does it need servicing?

Clean the heat exchanger annually in areas with good water quality, every six months where water is hard or scaling is likely.

How much space does the unit need?

Clear air inlet and outlet, plus maintenance access. Rooftop installation also requires a structural load check and vibration isolation.

Related reading

Request a quotation

Send the daily hot water volume, peak demand pattern, inlet water temperature, winter ambient design temperature and available power supply. We return a sizing sheet with model, capacity, tank volume and the assumptions used.

Longkang Environmental Equipment Co., Ltd. — air-source heat pump water heaters, water chillers and sludge dryers, supplied with sizing calculations, interface drawings, commissioning support and spare parts. Phone: +86 400-878-0280 | +86 130-0200-1280