Winter questions are about the gap between the label and the curve: what capacity actually remains at each ambient, how defrost behaves, and what has to be done so the machine survives a shutdown.
| Ambient | Typical capacity | What changes |
|---|---|---|
| +7 °C | Nominal | Reference point for ratings |
| 0 °C | 70–85% | Defrost becomes frequent |
| −5 °C | 60–75% | Low-temperature model expected |
| −15 °C | 40–55% | Injection or oversized coil required |
1. Where the limits actually are
Q1. Can the unit run at −5 °C?
Yes at reduced capacity, usually 60–75% of nominal depending on model and pool water temperature. The number that matters is the one on the derating curve at your design ambient, not the marketing range.
Q2. What about −10 °C or −15 °C?
A low-temperature model with a larger coil and modified defrost can hold 50–60% at −10 °C and 40–55% at −15 °C. Below that, most pool duties need either more installed capacity or a different heat source.
Q3. What separates a low-temperature unit from a standard one?
Evaporator surface area, defrost initiation and termination logic, often vapor injection into the compressor, a wider control range, and sometimes a crankcase heater. The casing is frequently identical, which is why the curve has to be read.
Q4. Does a mild region need low-temperature units?
Usually not for holding load, but cold snaps still occur. The check is whether the pool must hold temperature through the coldest week; if yes, size for it, even in a mild climate.
Q5. Is the low-temperature label a guarantee?
No. It describes a design intent. Two units with the same label can differ by 15 percentage points of capacity at −10 °C, and only the curve shows which is which.
2. Defrost and running behavior
Q5. Which defrost methods are used?
Reverse cycle, hot gas bypass, and on-demand initiation from coil temperature, air pressure drop or a combination. Time-based defrost is the least efficient because it defrosts whether or not frost exists.
Q6. How much does water temperature drop during defrost?
Normally a fraction of a kelvin in a large pool, because the water mass dominates. In a small pool with a large unit the drop can be visible on the display, which is why buffer volume helps.
Q7. What does an ice dam at the coil base mean?
Defrost water is refreezing at the bottom of the coil instead of draining. It blocks airflow, extends the next defrost and progressively removes capacity. Check the base drain, the defrost termination criterion and the fan delay.
Q8. Is frequent defrosting a fault?
Not always: humidity and air temperature drive it. It becomes a fault when it is clearly more frequent than in previous seasons at similar conditions — that points at coil fouling, low refrigerant charge or a sensor error.
Q9. Why is the unit louder in cold weather?
Higher pressure ratio means harder compressor work, defrost cycles produce rush of vapor, and fan speed changes. In addition, cold air carries sound further. If the change is abrupt rather than seasonal, check mounts and fan bearings.
3. Freeze protection and lay-up
Q9. How should the unit be handled when the pool closes for winter?
Either keep it running with freeze protection proven, or drain the water side fully and isolate the power with the circuit breaker locked off. Partial draining leaves water in the exchanger, which is the worst case.
Q10. Why do units split in winter?
Water left in the exchanger or pipework freezes, expands and bursts a tube or a fitting. It is almost always a lay-up error rather than an equipment failure, and it is excluded from most warranties.
Q11. Where should defrost water be discharged?
To a sloped drain that cannot freeze and cannot reach a walkway. A base that ponds water turns into an ice block and lifts the frame; check the drain before the first cold spell, not after.
Q12. What are the winter maintenance priorities?
Coil cleanliness, drain condition, defrost behavior, antifreeze concentration if used, and verification of the freeze protection setpoint. All five are cheap checks and each one prevents an expensive failure.
Q13. Does pipe trace heating help?
On exposed pipe runs in severe climates, yes, with a thermostat and a proven power supply. It does not protect the exchanger, which is why it is never a substitute for proper lay-up.
4. Cold starts, snow and acceptance
Q13. What matters at a cold start?
Crankcase heater operation, oil viscosity, gradual loading rather than a step to full capacity, and proven water flow before the compressor starts. Starting a cold machine at full load is how compressors are damaged.
Q14. Does snow load matter for rooftop units?
Yes: accumulated snow blocks the intake and crushes the coil guard, and the roof structure has to carry it. Either keep the unit above expected snow depth or provide a shelter that does not obstruct airflow.
Q15. How is winter capacity accepted?
By computing output from measured flow and temperature rise at the ambient of the day, then comparing with the derating curve. Waiting for the coldest night is not an acceptance method.
Q16. Do mild-region cold snaps need special handling?
Yes: protection settings that were never exercised, and undersized capacity both appear in the first cold snap. A pre-season check of antifreeze, drains and setpoints is the cheap answer.
Q17. Should the unit be restarted after long shutdown gradually?
Yes. Check insulation resistance, confirm water flow, run the pump for a period before starting the compressor, and inspect for frost damage. A machine that stood idle for months should not be energised and left.
Q18. Is a low-temperature unit always noisier?
Generally a little, because of the higher pressure ratio and larger air movement. Whether it matters depends on where the noise lands — at a bedroom wall, a few decibels are decisive.