Heat pumps · Chillers · Sludge drying systems
Drying · Reduction · Integrated

Mobile Sludge Dryers: When the Sludge Moves, Not the Plant

A fixed drying line assumes that the sludge is brought to the plant. Some projects work the other way: the sludge is spread across several small sites, each productive for only a few months. River dredging, sewer repair, construction dewatering and disaster response all fit this pattern. A trailer-mounted dryer travels to the sludge, dewaters it on site and reduces the mass before transport.

The concept is simple; the engineering is not. Three constraints dominate: vehicle dimensions, axle load and power supply. Ignore any one and the unit may be legally unable to travel or unable to run at the site.

This article covers the road limits, a 5 t/d example, power options and the economics of renting versus buying.

1. Road limits come before capacity

Under GB 1589-2016, a rigid truck is limited to 12 m overall length, 2.55 m width and 4 m height; a six-axle combination is limited to 49 t gross weight. The width limit is the binding constraint for a dryer. A fixed dryer is often 2.8–3.2 m wide, so it cannot be carried without narrowing the body. Narrowing increases the length for the same heat-transfer area, and the length then hits the 12 m limit. That is why mobile units are usually small.

Check the route as well: low bridges, narrow village roads and weight restrictions can rule out a vehicle that is legal on paper. Send the route survey to the transport contractor before specifying the unit.

2. Capacity: a 5 t/d example

For 5 t/d at 80% moisture dried to 30%, evaporation = 5 × (80 − 30) ÷ (100 − 30) = 3.57 t/d. Over 20 hours, that is about 179 kg/h. A 150–200 kg/h dehumidification capacity is a practical upper range for a small trailer unit.

Mobile dryers usually use a heat-pump dehumidification cycle rather than hot-air drying. Three reasons: the closed cycle does not emit a visible plume of warm humid air in a residential or riverbank area; the low temperature (60–70 °C) is safer near people; and the electrical demand is lower, which matters when the unit runs on a generator.

3. Power: grid first, generator second

A 55 kW mobile unit on a diesel generator may use 15–17 L/h. At CNY 7.5/L, fuel costs about CNY 113–128/h. On grid electricity at CNY 0.70/kWh, the same unit costs about CNY 38/h. Over 20 hours, the difference is roughly CNY 1,500–1,800/day; over a month, CNY 45,000–54,000. If a grid connection is available, use it.

The control cabinet needs vibration protection. On a rough road, chassis acceleration can exceed 2 g, and relays and terminals work loose. Fit anti-vibration mounts, use locking terminals and run a transport vibration test before delivery.

Generator sizing: the compressor is an inductive load and starting current can be three times the rated value. Size the generator at least 1.25 times the installed power; without a soft starter, allow 2 times. Otherwise the voltage dip resets the controller on every start.

4. What goes on the trailer — and what does not

The principle is “carry what is essential, leave what can stay on the ground”.

Odor control. This is often deleted at the proposal stage and then generates complaints. River dredging often takes place in urban channels with residents on both sides. Even low-temperature drying produces some odor. Fit at least an activated-carbon unit sized for 2,000–3,000 m³/h, with carbon replaced every three months.

Condensate collection. This 5 t/d unit produces about 3.5–4 t/d of condensate; larger trailer units can produce 4–7 t/d. COD is typically 800–2,500 mg/L. It cannot be discharged to the river. Carry a 3–5 m³ collection tank and tanker it to the sewer on each shift.

Spares. On a riverbank or construction site there is no nearby supplier. A broken belt can stop the unit for a day. Carry screw flights, chains, seals, fuses and basic tools for six months of wear parts.

Access. The unit needs about 8 m × 4 m of hard standing, a vehicle access route and a 380 V connection. Riverbanks and mudflats often lack all three. Verify the site before delivery, or the unit may arrive and be unable to enter.

5. Rent or buy

For a project shorter than about 12 months, renting is usually cheaper. For more than two years, buying is usually cheaper. Between one and two years, the decision depends on whether the unit can be redeployed to another site.

The transport saving is real. At 80% moisture, 5 t of wet sludge contains 4 t of water. Hauling 30 km at CNY 1.5/(t·km) costs CNY 225, or CNY 45/t of wet sludge. After drying to 30%, the mass is 1.43 t and the haul cost is CNY 64, or CNY 12.8/t of original wet sludge. The saving is about CNY 32/t. Add the disposal difference: at CNY 250/t for wet sludge and CNY 80/t for dried product, the reduction avoids a further CNY 170/t of original sludge. The combined benefit is substantial.

Item Wet sludge Dried to 30%
Mass for 5 t feed 5.0 t 1.43 t
Haul cost, 30 km at CNY 1.5/t·km CNY 225 CNY 64
Haul cost per t of original sludge CNY 45 CNY 12.8
Disposal cost at CNY 250/t vs CNY 80/t CNY 1,250 CNY 114

The disposal comparison assumes the dried product is accepted at the lower gate fee; confirm the receiving facility’s acceptance criteria before relying on it.

6. When not to use a mobile unit

Above 25 t/d. The road width limit caps the unit size. Multiple trailers can be paralleled, but a fixed station is usually better at that scale.

More than three years of continuous operation. The compact design sacrifices service access. Long, high-load operation raises maintenance cost above a fixed plant, which is larger but easier to service.

High sand content. River dredging can contain 30–50% sand, which wears screws and drums quickly. A mobile unit is hard to strip down on site. Use a fixed unit with wear liners, or separate the sand before drying.

Frequently asked questions

When is a mobile dryer the right choice?

When the sludge is at a temporary site, the plant cannot host a dryer, or transport of wet cake is the main cost. Dredging, pipe repair, emergency dewatering and small treatment sites are typical. It is not a substitute for a permanent high-throughput plant.

What limits trailer size?

Road width and height, bridge limits, axle load and the towing vehicle. A trailer that is legal empty may exceed axle limits when loaded. Check the route, including site access and turning radius, before specifying the unit.

How is power supplied on site?

From the site low-voltage supply, a generator or a temporary connection. Confirm the available capacity, voltage, phase and cable length. The dryer, fans, pumps and controls may need more than the site’s existing spare capacity.

How is capacity stated?

As wet metric tons per day at a stated moisture, or evaporation kilograms per hour. Mobile units are often limited by the available power and the drying area, not by the heat exchanger alone. Ask for both numbers at the site condition.

What permits are needed?

Transport, temporary discharge, odor and noise approvals, and possibly waste handling. The receiving route must be agreed before the unit arrives. A mobile dryer does not remove the need for a disposal contract.

How is the unit set up?

Level ground or pads, anchoring, power, water, condensate drainage and odor control. Allow access for sludge delivery and product removal. A unit that cannot be serviced on site becomes a bottleneck.

What should the contract cover?

Mobility, setup, commissioning, power and water supply, operator training, consumables, spare parts and demobilization. Clarify who owns the product and who pays for delays caused by site readiness.

How is performance verified?

Run a timed test at the site’s sludge, weigh the feed and product, measure moisture and power, and calculate evaporation. Compare with the quoted capacity at the same moisture and ambient condition.

Related reading

Dried sludge disposal · Municipal sludge drying · Sludge dryer efficiency loss