Municipal WWTP Sludge Drying: 20 t/d, 80% to 60%

A municipal wastewater treatment plant hands the drying building two numbers: 20 t/day of wet cake at 80% moisture. The drying building returns two numbers: the product mass and the product moisture. Between them is one quantity that decides the whole design: the water to be evaporated.

At 20 t/day and 80% moisture, the dry solids are 4 t/day. At 60% product moisture, the product is 10 t/day and the evaporation is 10 t/day. Every downstream figure — dryer area, power, condensate volume and odor flow — comes from that 10 t/day. The equipment should follow the water balance, not the other way round.

1. The water balance comes first

Product moisture Product mass Water evaporated Evaporation rate, 24 h
60% 10.0 t/d 10.0 t/d 417 kg/h
50% 8.0 t/d 12.0 t/d 500 kg/h
40% 6.67 t/d 13.3 t/d 554 kg/h

The step from 60% to 50% raises the evaporation by 20%; the step from 50% to 40% raises it by only 11%. The same ten-point change costs different amounts because the water removed near 40% is closer to adsorbed and bound water, and the drying rate falls. The target moisture should be selected from the disposal route, not from a desire to produce the driest cake.

2. Three upstream interfaces decide success

Cake moisture. A plate-and-frame press typically produces 75–80% moisture; a centrifuge 78–82%. The difference is not only the level but the stability: a plate press discharges in batches and varies by about 2 points between batches; a centrifuge drifts with feed concentration and polymer dose and can vary 3–5 points within a shift. The dryer is sized on the moisture, so a feed that drifts from 80% to 84% raises the cake mass from 20 to 25 t/d at the same dry solids, and the evaporation rises by 20%. The dryer does not alarm; it produces wetter cake.

Conveying. Municipal cake at 80% is a paste, sticky from residual polymer. A shaftless screw conveyor can blind at the flight roots. A belt plus scraper, with the incline below 20° and a plow at the transfer, is more reliable. Above 15 m, add a magnetic separator and a trash trap: plastic sheet or woven-bag fragments will jam the cutting bars and cause an unplanned stop.

Buffer storage. The dewatering building often runs one shift; the dryer runs continuously. The 8–12 hour difference is the buffer. For 20 t/day, provide 7–10 t, or 8–10 m³ at a bulk density of 0.9–1.1 t/m³. The bin needs an active anti-bridging device; a 60° cone alone will still bridge at 82% moisture. Fit a level sensor and an odor extraction connection, or odor will travel back into the dewatering building.

3. Select the product moisture from the disposal route

Mixed landfill under GB/T 23485-2009 usually requires below 60% moisture. That is the most common target and the lowest-cost option for a 20 t/day project. Incineration co-firing needs a drier cake: above about 45% moisture, the heating value does not cover the latent heat of the water, and the co-firing ratio cannot rise. Cement kiln and brick making generally take 30–40%; below that, the evaporation enters the bound-water region and the drying rate falls sharply. Land application has its own sludge-quality and hygiene requirements; drying only removes water and does not replace stabilization or disinfection.

The 60% route is not a free choice. It must be confirmed with the landfill or the offtaker, including the test method and the seasonal acceptance. A design that assumes 60% while the offtaker only accepts 55% will fail at the gate.

4. Energy and operating cost

Heat-pump dehumidification drying typically removes 3–4 kg of water per kWh, or 250–350 kWh per metric ton of water. This includes the compressor, circulation fan, cutting and conveying, but not the odor fan or condensate treatment. It is lower than electric or steam drying because the latent heat is recovered when the humid air condenses on the evaporator and returns to the refrigerant, not because the compressor is unusually efficient.

For 10 t/day of evaporation at 300 kWh/t water, the daily power is 3,000 kWh. At 0.65 CNY/kWh, the daily cost is 1,950 CNY, or 97.5 CNY per metric ton of incoming cake. The figure is not very sensitive to ambient temperature: a 10 K fall in feed temperature adds only about 116 kWh, 4% of the total. It is sensitive to humidity: in a humid season the dehumidification temperature difference falls and the specific energy can rise 10–15%.

Cost item Basis CNY/t incoming cake
Drying electricity 300 kWh/t water, 0.65 CNY/kWh 97.5
Labor 3 shifts, 8,000 CNY/person/month, 600 t/month 40.0
Maintenance and spares Filters, belts, bearings, refrigerant 10.0
Odor control and cleaning Chemicals, carbon, water 10.0
Drying operating cost — 157.5

The disposal fee is the larger number. At 260 CNY/t and a 50% mass reduction, the disposal saving is 130 CNY/t incoming. The break-even disposal price is about 315 CNY/t: below it, drying is mainly volume reduction and stabilization; above it, the mass reduction starts to pay. The negotiation belongs with the disposal contract, not only with the dryer supplier.

5. Condensate and odor have to go somewhere

The evaporated water does not disappear. Of the 10 t/day, about 8.5–9.5 t/day condenses; the rest leaves with the product or is lost through small leaks. The condensate typically has COD 500–3,000 mg/L and ammonia 100–500 mg/L, which does not meet the indirect-discharge limits of GB 18918-2002. The usual route is to return it to the plant inlet at 1–2% of the daily flow; if the anaerobic stage is already at capacity, strip or breakpoint-chlorinate the ammonia first.

Size the odor flow by exhaust, not by room volume. A closed-cycle dryer exhausts only 10–15% of the circulation flow to control humidity; a 20 t/day machine typically exhausts 1,500–3,000 m³/h. That low flow is a real advantage over a hot-air dryer, whose exhaust is an order of magnitude larger and drags the scrubber, fan and carbon bed up with it. The odor is mainly hydrogen sulphide and ammonia; caustic scrubbing followed by biological treatment or carbon is the usual sequence. If the carbon is placed first, its life is short.

Watch two site readings: the drying room should be at −20 to −50 Pa relative to the dewatering building, and the scrubber differential pressure should trigger a carbon change at a 30% rise, not a fan-speed change.

6. Wet weather and part-load operation

In a combined sewer area, wet weather raises the inflow by 20–30% and the sludge mass follows. If the dry solids stay at 4 t/day and the moisture rises from 80% to 82%, the cake mass becomes 22.2 t/day, the product stays at 10 t/day and the evaporation rises from 10 to 12.2 t/day, 22% more. A machine cannot be “overclocked” to cover this. Either provide margin, extend the buffer or agree a relaxed product moisture in the wet season.

Three responses have different costs. Sizing the evaporation at 1.2 times the dry-weather value leaves the machine at about 70% load for most of the year, where the dehumidification ratio is often better. Extending the buffer from 8 to 12 hours trades storage for time and suits a few intense storms. Relaxing the product from 60% to 65% depends on the offtaker. The worst choice is a single oversized machine running below 40% load, where the dehumidification ratio falls sharply.

At 20 t/day and 417 kg/h, continuous operation is more efficient than start-stop. Each start has a cool-down, condensation and stabilization phase, and frequent starts reduce the average dehumidification ratio by 5–10%. Run 24 hours and put the stops into planned maintenance.

Key figures for the 20 t/d case

The 20 t/d case is a 60% product case, not a generic dryer rating. At 78–82% feed, the plant evaporates about 417 kg/h and produces 10 t/d of cake at 60%. Those two numbers set the whole line: dewatering, dryer size, condensate, odor and buffer storage. The table below is the operating envelope to put in the tender.

Item Value for this case How to verify
Feed moisture 78–82% Daily cake weight and inline moisture meter
Evaporated water 417 kg/h Feed mass minus product mass, checked daily
Dewatering electricity 250–350 kWh/t water Separate meter; exclude the odor fan
Condensate 85–95% of evaporated water Sump level plus flow totalizer
Exhaust air 10–15% of loop air Fan frequency and duct static pressure
Room pressure −20 to −50 Pa Differential gauge, drying room to corridor
Buffer storage 8–12 h Level sensor plus daily physical inventory

Product moisture follows the disposal route, not the dryer’s capability. Mixed landfill uses 60%; co-firing needs 40–45%; cement kiln or brick making needs 30–40%. A 60% product is the cheapest permitted route; 40% is a fuel specification. Do not promise 30% unless the receiving site has agreed to the material and the dryer has been sized for the falling-rate load.

Check the interfaces before the dryer. The dewatering house must deliver a consistent cake, the dryer must accept that cake without bridging, and the product conveyor must handle the drier, dustier material. If any of the three is undersized, the 20 t/d case will run at lower throughput even when the dryer is correct. If the odor fan shares the meter, the apparent specific energy will be 10–20% too high and the guarantee will be wrong. Condensate is 85–95% of evaporated water; the rest leaves with the exhaust or stays in the cake. For the equipment boundary, see the sludge dryer range.

Common questions

How much water must a 20 t/d feed evaporate from 80% to 60%?

About 10 metric tons per day, or roughly 417 kg/h. Add 15–20% margin for fouling and ambient, so select a dryer rated near 480–500 kg/h.

What is the difference between 60% and 40% product?

At 60% the evaporation is 10 t/day; at 40% it is 13.3 t/day. The power difference is about 1,000 kWh/day, or 650 CNY/day at 0.65 CNY/kWh.

Can the condensate go to the sewer?

Not directly. COD 500–3,000 mg/L and ammonia 100–500 mg/L exceed typical indirect-discharge limits. Return it to the plant inlet at 1–2% of flow, or treat it first.

Why is the buffer bin so large?

Because the dewatering building and the dryer run on different schedules. An 8–12 hour buffer for 20 t/day is 7–10 t, or 8–10 m³.

What happens in the wet season?

The cake mass and evaporation can rise by about 22%. Provide margin, buffer or a temporary moisture allowance; do not rely on running the machine beyond its rating.

What decides whether drying pays?

The disposal price. At 260 CNY/t the saving is 130 CNY/t; the break-even is about 315 CNY/t. The dryer’s electricity is only part of the story.

What upstream interfaces decide?

Dewatering performance, storage and the disposal route. A dryer cannot fix a cake that varies 5% in moisture. The project is decided before the dryer.

How do I verify 20 t/d?

Weigh the feed and product, measure moisture and power over a week. Compare with the guarantee boundary. A single test is not a plant acceptance.

Further technical reading

LONGCOM can build the water balance, select the product moisture from the disposal route and size the buffer, odor and condensate systems for a municipal plant. For a 20 t/day case review, contact 400-878-0280 or 13002001280.