Sludge drying is a water-removal business. The saleable product is the dry solids; the water is the burden. Yet many projects specify a dryer by feed tonnage — “10 metric tons per day” — without stating the inlet and outlet moisture. That specification is incomplete, and it usually leads to a dryer that is too small.
The reason is the mass balance. Going from 80% moisture to 30% does not remove 50% of the mass; it removes about 71% of the feed as water. The dryer’s capacity is set by how much water it must evaporate, not by how much wet sludge enters.
This article gives the formulas, a table of common moisture targets, a worked 10 t/d example and the energy check. Numbers are illustrative; use the plant’s actual analysis.
1. Wet basis and dry basis: define the denominator
Moisture is usually reported on a wet basis: the mass of water divided by the total wet mass. A sludge at 80% moisture contains 80 kg water and 20 kg dry solids per 100 kg. The dry-solids fraction is 20%.
The dry basis expresses water as a multiple of dry solids: 80% wet basis = 4 kg water per kg dry solids, or 400% dry basis. The two are not interchangeable. A contract that says “80% moisture” but the laboratory reports dry basis will be off by a factor of five.
Always write “% wet basis” in the specification and the test report. If the laboratory uses dry basis, convert before comparing.
| Wet basis | Dry solids | Water per 100 kg | Dry basis |
|---|---|---|---|
| 99% | 1% | 99 kg | 9,900% |
| 95% | 5% | 95 kg | 1,900% |
| 80% | 20% | 80 kg | 400% |
| 60% | 40% | 60 kg | 150% |
| 30% | 70% | 30 kg | 43% |
| 10% | 90% | 10 kg | 11% |
2. The evaporation formula
For a feed mass Mf at moisture w1 (wet basis, as a fraction) dried to w2:
Mproduct = Mf × (1 − w1) / (1 − w2)
Mevaporated = Mf × (w1 − w2) / (1 − w2)
The dry-solids mass is conserved: Mf × (1 − w1) = Mproduct × (1 − w2). That conservation is the basis of every dryer calculation.
For 1 metric ton of 80% sludge dried to 30%: product = 1 × 0.2 / 0.7 = 0.286 t; evaporated = 1 × (0.8 − 0.3) / 0.7 = 0.714 t. The product is 28.6% of the feed, and 71.4% leaves as water vapor.
Dried to 10%: product = 0.2 / 0.9 = 0.222 t; evaporated = 0.7 / 0.9 = 0.778 t. The extra 20 percentage points of dryness remove another 64 kg of water per metric ton of feed — 9% more evaporation for a product that is only 78% of the mass at 30%.
3. Worked example: 10 t/d from 80% to 30%
Feed: 10 t/d at 80% moisture. Dry solids: 2 t/d. Product at 30%: 2 / 0.7 = 2.857 t/d. Water evaporated: 10 − 2.857 = 7.143 t/d.
If the plant runs 20 h/d, the average evaporation rate is 357 kg/h. If it runs 24 h, 298 kg/h. The dryer must be specified at the design rate, not the average, and with a margin for fouling and seasonal load.
| Item | Value | Basis |
|---|---|---|
| Feed | 10 t/d | 80% moisture |
| Dry solids | 2.0 t/d | 20% of feed |
| Product at 30% | 2.86 t/d | 2 / 0.7 |
| Water evaporated | 7.14 t/d | 10 − 2.86 |
| Evaporation at 20 h/d | 357 kg/h | 7,140 / 20 |
| Evaporation at 24 h/d | 298 kg/h | 7,140 / 24 |
4. Why dryer capacity is rated on evaporation
A dryer catalog may say “10 t/d” without stating the moisture. That rating might mean 10 t/d from 80% to 30%, or from 60% to 10%, which are very different duties. Always ask for the evaporation rate in kg/h at the specified inlet and outlet moisture.
The heat transfer surface, airflow and residence time are sized by evaporation. The feed tonnage is only an input to the mass balance. Two dryers with the same “10 t/d” label can differ by 50% in evaporative capacity.
Also check the product’s residence time. A dryer that evaporates the right amount but holds the sludge for too short a time may produce a wet, sticky product; too long a time may over-dry and create dust or fire risk.
5. Energy check: how much heat per kg of water
The latent heat of water at 100 °C is about 2,260 kJ/kg, or 0.63 kWh/kg. A direct dryer with 70–80% thermal efficiency needs about 0.8–0.9 kWh per kg of water evaporated. An indirect steam dryer with 80–90% efficiency needs 0.7–0.8 kWh/kg, expressed as heat input.
For 7.14 t/d, the heat demand is roughly 5,000–6,400 kWh/d, or 210–270 kW average over 24 h. A heat-pump dryer at 0.30–0.40 kWh/kg of water uses 2,100–2,900 kWh/d, but the low temperature means a longer residence time and a larger footprint.
Do not compare the electricity input of a heat-pump dryer with the fuel input of a thermal dryer without converting both to primary energy. A heat pump at COP 3.0 delivers 3 kWh of heat per kWh of electricity; a gas burner at 85% delivers 0.85 kWh per kWh of gas. The cost comparison depends on the electricity-to-gas price ratio.
6. Moisture targets and the marginal cost of dryness
| Target | Product per t feed | Water evaporated | Typical route |
|---|---|---|---|
| 60% | 0.50 t | 0.50 t | Lime stabilization, some landfills |
| 40% | 0.333 t | 0.667 t | Landfill cover, co-processing |
| 30% | 0.286 t | 0.714 t | Incineration, cement kiln |
| 10% | 0.222 t | 0.778 t | Fertilizer, long storage |
The last step from 30% to 10% removes only 64 kg of water per metric ton of feed, but it can double the dryer’s residence time and increase the fire risk. Ask whether the disposal route really requires 10%, or whether 30% is acceptable. The marginal cost of the last few percentage points is often the highest.
Frequently asked questions
What is the basic moisture-reduction formula?
Dry solids stay constant. If feed mass is F at moisture m1 and product mass P at m2, then F(1−m1)=P(1−m2). Evaporated water is F−P. Use decimals, not percentages, and keep the same basis (wet mass).
How do I calculate evaporation for 100 t/d?
At 80% moisture, dry solids are 20 t. At 30% moisture, product mass is 20/0.7 = 28.6 t, so water evaporated is 100−28.6 = 71.4 t/d. This is the number that sizes the heat pump, condenser and air flow.
What is the difference between moisture and water content?
Moisture is water divided by total wet mass; water content is sometimes used as water divided by dry solids. Mixing the two causes large errors. State the basis in every calculation and in the contract.
How do I size a dryer from evaporation?
Use water evaporation per hour, the unit’s specific energy at the design condition, and the required operating hours. Then add margin for moisture variation and fouling. Do not size from wet tonnage alone.
Why does dry-solids mass stay constant?
Drying removes water, not solids, unless dust is lost. Small dust losses and sampling errors explain differences between calculated and measured product. Reconcile with measured dry-solids content.
How do I check the calculation?
Calculate feed dry solids, product mass and evaporated water, then compare with the measured product mass and moisture. A difference above a few percent means a measurement or dust-loss problem, not a different formula.
What units should be used?
Use metric tons per day for mass and kilograms per hour for evaporation, and state moisture as a percentage of wet mass. Convert consistently; a unit error is the most common reason a dryer looks undersized.
How does this set the cost?
Evaporated water drives energy, condenser and air flow. Mechanical dewatering reduces evaporated water before the dryer, so the same final product needs less thermal energy. Calculate both routes with the same mass balance.