Specific energy for a sludge dryer is usually quoted as 0.25–0.45 kWh per kg of water evaporated. The range is real, but a number without a boundary and a meter is not a guarantee. Two plants can quote 0.35 kWh/kg and mean different things: one at the compressor, one at the plant meter, one excluding the off-gas fan.
This article defines the boundary, the three meters and the test that makes a kWh/t guarantee enforceable.
Three meters
The first meter is the feed scale. It gives the wet metric tons and the feed moisture, if the moisture is sampled and averaged. The second is the product scale; it gives the dry solids capture and the product moisture. The third is the electrical meter at the plant boundary; it gives the kWh.
The specific energy is the meter kWh divided by the water removed. The water removed is the feed water minus the product water, calculated from the two scales and the moisture samples. A guarantee based on the feed scale alone can be met by over-drying or by under-feeding; a guarantee based on the product scale alone can be met by recycling dry product.
| Meter | Measures | Use |
|---|---|---|
| Feed scale | Wet metric tons, feed moisture | Water input |
| Product scale | Dry metric tons, product moisture | Water output |
| kWh meter | Compressor, fans, pumps, conveyor | Energy input |
The boundary
The plant boundary should include the compressor, the condenser fan, the evaporator fan, the chamber circulation fan, the feed and discharge conveyors, the condensate pump and the control panel. It should exclude the upstream dewatering, the off-gas treatment, the building HVAC and the lighting, unless the contract says otherwise.
If the off-gas treatment is included, the specific energy can rise by 10–20%. If the feed conveyor is excluded, the number can fall by 5–10%. A guarantee that does not state the boundary is not comparable with another supplier’s number.
| Included | Usually excluded |
|---|---|
| Compressor | Upstream dewatering |
| Condenser and evaporator fans | Off-gas scrubber / oxidizer |
| Chamber circulation fan | Building HVAC |
| Feed and discharge conveyors | Lighting and office load |
| Condensate pump | Sludge transport |
| Control panel | Water treatment |
The example
10 t/d at 80% feed, 30% product. Dry solids 2 t/d, product 2.86 t/d, water removed 7.14 t/d. At 0.35 kWh/kg, the energy is 7,140 kg × 0.35 = 2,499 kWh/d. At CNY 0.70/kWh, the electricity is CNY 1,750/day, or CNY 175 per wet metric ton.
The same plant at 0.30 kWh/kg uses 2,142 kWh/d and saves CNY 250/day. Over 300 days, that is CNY 75,000/year. The difference between 0.30 and 0.35 is not a rounding error; it is a guarantee issue.
Correcting to a common feed
Specific energy depends on the feed moisture. A dryer tested at 78% feed removes less water per metric ton than one tested at 82%. A fair guarantee states the feed moisture and corrects the measured value to the design feed. The correction should use the water removed, not the wet metric tons.
The guarantee should also state the ambient temperature and the product moisture. A dryer tested at 15 °C ambient and 35% product is flattered compared with a 30 °C ambient and 25% product test. The test condition is part of the number.
The test
Run for 72 hours at steady feed and product moisture. Record the feed and product scales every hour, the kWh meter every hour and the moisture samples every 4 hours. The average specific energy is the total kWh divided by the total water removed, not the average of hourly ratios. A ratio of averages is not the same as an average of ratios.
The test should include a startup and a shutdown, or state that they are excluded. A 72-hour test that starts after the dryer is already hot excludes the startup energy, which is a real cost. A test that stops before the shutdown excludes the purge and cooldown.
Energy is not the only cost
The kWh/t number excludes the maintenance, the consumables and the off-gas treatment. A dryer at 0.30 kWh/kg with a 5-year coil life may cost more than one at 0.35 with a 10-year coil. The comparison should use the lifecycle cost, not the electricity alone.
The consumables include the filter bags, the belt, the bearings and the refrigerant. A heat-pump dryer has a sealed refrigerant circuit, but a leak is a cost and an environmental issue. Ask for the refrigerant charge and the leak-detection schedule.
The operating record
Keep a daily log of feed metric tons, feed moisture, product moisture, kWh, condensate flow and coil ΔP. The log is the evidence for the guarantee and the baseline for the next service. A plant that cannot show a 72-hour record cannot prove a specific energy, and a supplier cannot defend a number without one.
The log should be signed by the shift operator and reviewed monthly. A single anomalous day is not a trend; three days in a row is. The trend is what tells you the coil is fouling or the feed is wetter, before the product misses the specification.
Boundary
This method is for a single dryer with a stable feed. A plant with a variable feed or a batch operation needs a longer test and a regression, not a single average. A guarantee that is met on a good week and missed on a wet week is not a guarantee.
Common questions
What is a good kWh/kg for a sludge dryer?
0.25–0.45 kWh/kg water for a heat-pump dryer, depending on feed moisture, product moisture and ambient. A single number without a boundary is not comparable.
Which meters are needed?
A feed scale, a product scale and a kWh meter at the plant boundary. Moisture samples are needed to convert metric tons to water.
What should the boundary include?
Compressor, fans, conveyors, condensate pump and controls. Exclude upstream dewatering and off-gas treatment unless the contract includes them.
How much does 0.05 kWh/kg cost?
On 7.14 t/d of water, 0.05 kWh/kg is 357 kWh/d. At CNY 0.70/kWh, it is CNY 250/day, or CNY 75,000/year at 300 days.
Should the test include startup?
State it explicitly. A test that starts hot excludes the startup energy; a test that stops before purge excludes the shutdown. Both are real costs.
Why correct to the design feed?
Specific energy depends on feed moisture. A dryer tested at 78% removes less water per metric ton than one tested at 82%. Correct on water removed, not wet metric tons.
What boundary should the guarantee use?
The dryer plant battery limit: feed scale, product scale, dryer and auxiliaries. Exclude upstream dewatering and downstream transport. State the moisture basis and the ambient.
How do I verify the meters?
Calibrate before and after the test, record the pulse factor and witness the reading. A guarantee without meter calibration is a discussion, not a number.
Further technical reading
For the three denominators, see Sludge Dryer kWh/t: Three Denominators, Five Times Apart. For dewatering, see Sludge Dewatering Before Drying. For installation, see Sludge Dryer Installation: Ten-Day Sequence. For filter press integration, see Filter Press with Low-Temperature Drying.
Related reading
Sludge dryer energy cost · Dryer FAT witness test · Seven inputs for a guarantee