Sludge Dryer kWh/t: Three Denominators, Five Times Apart

A sludge dryer datasheet often says “0.3 kWh/kg water” or “300 kWh/t”. The number looks simple; it is the most misunderstood parameter in procurement, because the “t” can mean wet cake, water evaporated or dry solids. The three values differ by a factor of five.

One supplier says 214 kWh per metric ton; the owner calculates 1,070 per metric ton of dry solids. Both are right. They are describing different denominators. At acceptance, each side uses its own arithmetic and the argument begins.

1. One case, three denominators

Take 1 t of cake at 80% moisture dried to 30%. It contains 0.2 t of dry solids and 0.8 t of water. At 30% moisture, the product mass is 0.2 ÷ 0.7 = 0.286 t, so the water evaporated is 1 − 0.286 = 0.714 t.

At a specific energy of 300 kWh per metric ton of water:

Per metric ton of wet cake: 0.714 × 300 = 214 kWh/t.

Per metric ton of water: 300 kWh/t (the definition).

Per metric ton of dry solids: 214 ÷ 0.2 = 1,070 kWh/t DS.

Denominator What it measures Typical use Value for 80% to 30%
Wet cake Incoming mass Power bill, disposal cost 214 kWh/t
Water evaporated Water removed Dryer efficiency, comparison 300 kWh/t
Dry solids Absolute solids Cross-moisture comparison 1,070 kWh/t DS

2. Why the dry-solids number can look absurd

At higher feed moisture the dry-solids denominator explodes. At 99% feed, 1 t of dry solids corresponds to 100 t of wet sludge, and about 96.7 t of water must be evaporated. At 300 kWh/t water, that is about 29,000 kWh per metric ton of dry solids. The number is arithmetically correct and commercially useless for a normal dryer: such sludge should be mechanically dewatered first, not dried from 99%.

Feed moisture Dry solids Water to 30% product kWh/t wet cake kWh/t DS
99% 1% 96.7 t 296 29,600
97% 3% 31.9 t 287 9,570
90% 10% 8.57 t 257 2,570
80% 20% 0.714 t 214 1,070
70% 30% 0.571 t 171 571
60% 40% 0.429 t 129 321

The same machine at 99% and 60% feed differs by more than a factor of two on the wet-cake basis and by a factor of 90 on the dry-solids basis. A quotation that says only “300 kWh/t” without the feed moisture is not a specification.

3. Fix the boundary as well as the denominator

The specific energy should state what is included: compressor, circulation fan, cutting and conveying, or also odor fan, condensate pump and controls. A dryer quoted at 300 kWh/t water for the thermal package may draw 330–350 kWh/t at the meter once the auxiliaries are included. Both numbers can be honest; they are different boundaries.

State the feed moisture range, the product moisture, the load factor and the test window. A typical heat-pump dryer removes 3–4 kg of water per kWh, corresponding to a specific energy of 250–350 kWh/t water and a SMER of 3.0–3.5 kg/kWh. A SMER above 4.0 is a good result; a claim of 5.0 at 80% feed deserves a test.

Acceptance is usually measured within 30 days of commissioning, while the heat exchangers are clean. After that, fouling and compressor degradation raise the specific energy by about 3–5% a year. A rise above 8% is not normal; check condenser cleaning, refrigerant charge and fan belts.

4. Compare quotations by converting to one basis

Supplier A quotes 210 kWh/t wet cake. Supplier B quotes 0.33 kWh/kg water. At 80% feed and 30% product, A is 210 ÷ 0.714 = 294 kWh/t water; B is 330 kWh/t water. A is about 11% better, even though the raw numbers look far apart.

If the conversion still leaves a difference above 30%, ask two questions: what feed moisture was assumed, and what load factor was used? A machine tested at full load and a machine tested at 60% load are not comparable. A dryer quoted at 80% feed but installed at 85% will remove 30% more water and show a higher specific energy, even if the machine is exactly as specified.

5. Put the number into the operating cost

For 20 t/day of cake at 80% to 30%, the water evaporated is 14.29 t/day. At 300 kWh/t water, the daily power is 4,284 kWh. At 0.65 CNY/kWh and 330 days, the annual cost is about 919,000 CNY. The specific cost is about 139 CNY per metric ton of incoming cake.

That figure only makes sense next to the disposal cost. If disposal is 400 CNY/t, drying 20 t to 5.71 t saves about 5,720 CNY/day and costs about 2,785 CNY/day in electricity, a net 2,929 CNY/day. If disposal is below about 200 CNY/t, the electricity absorbs most of the benefit; the case then rests on volume reduction, stability or compliance, not on direct saving.

The dryer does not create the saving by itself. It changes the mass and the route. The specific energy is one input to that comparison, not the conclusion.

Key figures and contract conditions for kWh/t

The arithmetic is simple once the denominator is fixed. The contract problem is that three different denominators can all be called “per metric ton”, and the acceptance condition is often left out. The table brings the figures and the conditions together.

Item Reference value or condition Why it matters
Denominator Wet cake, water evaporated or dry solids 214, 300 and 1,070 kWh/t for 80% to 30% are the same machine
SMER 3.0–3.5 kg water/kWh; above 4.0 is strong Converts specific energy into a comparable efficiency
Feed moisture Design value, commonly 80% At 85%, water removal rises about 30% and kWh/t rises
Product moisture Design value, commonly 30% Drying to 20% adds about 5% water removal
Load factor 100% for the guarantee test At 60% load, specific energy can rise 15–25%
Test window First 30 days after commissioning Clean heat exchangers give the baseline; 3–5% annual rise is normal
Contract wording kWh/t water, feed range, product moisture, load factor, test window Without these four conditions, a guarantee cannot be verified

Write the guarantee on evaporated water, not on wet cake. If the guarantee is on wet cake, a wetter feed penalizes the supplier and a drier feed penalizes the owner; on water, both sides settle against the same physical quantity. State the feed moisture range and the adjustment method outside that range, and state who pays for cleaning during the guarantee period.

The baseline belongs to the clean machine. A test in the first 30 days establishes the reference; after that, fouling and compressor wear move the number. A rise of 3–5% per year is normal, and above 8% calls for a condenser clean, a refrigerant check and a fan-belt inspection. Do not accept a single spot reading taken at an unknown load factor. Longcom’s sludge dryer page lists the heat-pump and belt configurations with their design moisture ranges.

Common questions

Is 0.3 kWh/kg per kg of wet cake or water?

Per kg of water evaporated. At 80% feed, the wet-cake equivalent is 0.214 kWh/kg, about 40% lower.

Which denominator should a tender use?

Use kWh per metric ton of water for the performance guarantee, and state the feed and product moisture, the boundary and the test window. Use kWh per metric ton of wet cake for the operating budget.

Why is the dry-solids number so high?

Because 1 t of dry solids corresponds to 5 t of 80% cake or 100 t of 99% sludge. It is a cross-moisture comparator, not a settlement basis.

Is 300 kWh/t water a good result?

It corresponds to a SMER of 3.33 kg/kWh, within the normal 3.0–3.5 range. Above 4.0 is strong; below 2.5 needs a review of the technology and the boundary.

Why does the measured value rise after a year?

Fouling on the heat exchangers, refrigerant loss and fan or belt wear. A 3–5% annual rise is normal; above 8% needs maintenance, not a new machine.

Can I compare a heat-pump dryer with a steam dryer on kWh/t?

No. One is electricity and the other is heat. Convert both to primary energy or to cost, and state the conversion factor.

Which denominator?

Wet cake, dry solids or water evaporated. The same meter reading gives very different kWh/t. Fix the basis before comparing quotes.

How do I compare quotes?

Convert every quote to kWh per metric ton of water evaporated, at the same moisture and boundary. Then compare. A lower number on another basis is not a better dryer.